Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchSiguranță AI

analiza aiqbench

This study exposes critical fragility in frozen hematology foundation models, revealing that top-performing encoders like DinoBloom-L suffer severe accuracy drops and calibration collapse when deployed across different scanners or preparation pipelines. The research demonstrates that standard linear probes fail to predict target robustness, while specific training-free adaptations like Class-Balanced Re-standardization offer partial mitigation against class-prior shifts. For clinical AI deployment, these findings underscore the necessity of auditing not just in-domain accuracy but also cross-dataset calibration and exposure bias before trusting any frozen model in production environments.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Can You Trust Frozen Hematology Foundation Models under Acquisition Shift?

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2608.25148v1 Announce Type: cross Abstract: Frozen hematology foundation-model (FM) embeddings reach near-saturated in-domain white-blood-cell (WBC) accuracy, but clinical deployment demands reliability across scanners, sites, stains and preparation pipelines. We audit 15 frozen encoders (hematology, pathology, and general vision) across four public single-cell acquisition domains along two axes: accuracy robustness and calibration. In-domain linear-probe macro-F1 is saturated (0.98-0.997), yet cross-dataset macro-F1 drops 34-72% and rankings re-order: DinoBloom-L, the in-domain best, falls to 10th of 15 on the most-shifted target (MLL23) at the benchmark's shared 224-px input, behind RedDino and several general and pathology encoders. Rank transfer is probe-dependent: 1-NN retrieval is more stable on average than a source-fitted linear head (median $\rho$ 0.65 vs 0.45), but neither probe universally predicts target robustness. Calibration also collapses: source-trained probes are nearly calibrated in-domain (expected calibration error, ECE, 0.004) but confidently wrong off-domain (ECE 0.35), and source-fitted temperature scaling transfers poorly. We further audit pretraining exposure and identify MLL23 as DinoBloom's internal cohort; because DinoBloom's only held-out dataset is also our source domain, this benchmark cannot isolate exposure from scanner-associated shift. Label-free adaptation and marginal-entropy-based model selection appear safe under balanced evaluation but fail under realistic WBC class-prior shift. Class-Balanced Re-standardization (CBR), a training-free pseudo-label-balanced feature normalization, improves all evaluated target-prior scenario means and partially improves calibration, although encoder-level exceptions and residual miscalibration remain. Hematology FM benchmarks must therefore jointly audit accuracy, calibration, exposure, and class-prior robustness.

Abstract:Frozen hematology foundation-model (FM) embeddings reach near-saturated in-domain white-blood-cell (WBC) accuracy, but clinical deployment demands reliability across scanners, sites, stains and preparation pipelines. We audit 15 frozen encoders (hematology, pathology, and general vision) across four public single-cell acquisition domains along two axes: accuracy robustness and calibration. In-domain linear-probe macro-F1 is saturated (0.98-0.997), yet cross-dataset macro-F1 drops 34-72% and rankings re-order: DinoBloom-L, the in-domain best, falls to 10th of 15 on the most-shifted target (MLL23) at the benchmark's shared 224-px input, behind RedDino and several general and pathology encoders. Rank transfer is probe-dependent: 1-NN retrieval is more stable on average than a source-fitted linear head (median $\rho$ 0.65 vs 0.45), but neither probe universally predicts target robustness. Calibration also collapses: source-trained probes are nearly calibrated in-domain (expected calibration error, ECE, 0.004) but confidently wrong off-domain (ECE 0.35), and source-fitted temperature scaling transfers poorly. We further audit pretraining exposure and identify MLL23 as DinoBloom's internal cohort; because DinoBloom's only held-out dataset is also our source domain, this benchmark cannot isolate exposure from scanner-associated shift. Label-free adaptation and marginal-entropy-based model selection appear safe under balanced evaluation but fail under realistic WBC class-prior shift. Class-Balanced Re-standardization (CBR), a training-free pseudo-label-balanced feature normalization, improves all evaluated target-prior scenario means and partially improves calibration, although encoder-level exceptions and residual miscalibration remain. Hematology FM benchmarks must therefore jointly audit accuracy, calibration, exposure, and class-prior robustness.

Accepted at the HemaRAI 2026 workshop (MICCAI 2026 satellite event), oral presentation; to appear in MICCAI 2026 Satellite Events, LNCS, Springer. 25 pages (10 main incl. references + 15 supplementary), 4 figures. Project page: this https URL

Computer Vision and Pattern Recognition (cs.CV); Artificial Intelligence (cs.AI); Quantitative Methods (q-bio.QM)

arXiv:2608.25148 [cs.CV]

(or arXiv:2608.25148v1 [cs.CV] for this version)

Text integral sub licența deschisă a publicației · 285 cuvinte

Subiecte conexe