BioSync introduces a transformer-based architecture that fuses multimodal physiological data—such as heart rate variability, EEG, and speech—to generate a composite digital biomarker with marginal improvements over standard feature concatenation. While the model demonstrates robustness to modality dropout in synthetic cohorts, its reliance on simulated data highlights the critical need for validation on real-world patient populations before clinical deployment. This work advances the methodological frontier of cross-modal fusion but currently lacks the empirical grounding required for immediate practical application in healthcare settings.
BioSync: Transformer-Based Cross-Modal Fusion for a Multimodal Physiological Digital Biomarker
arXiv:2609.04504v1 Announce Type: new Abstract: Cardiac, neural, behavioral, and speech measurements from wearable and mobile devices provide partial, noise-sensitive views of physiological state. BioSync combines these measurements into the \textbf{BioSync Index (BSI)}, a continuous composite digital biomarker defined under the BEST framework. The model applies multi-head self-attention to modality tokens and adds a linear branch whose hypothesis class includes standard feature concatenation. This architecture is motivated by latent-variable measurement theory and by the possibility that joint observations contain information unavailable from individual modalities. We evaluated BioSync on two literature-informed synthetic cohorts: a four-modality cognitive-decline cohort using HRV, EEG, actigraphy, and speech, and a metabolic-autonomic cohort structured around the public AI-READI wearable schema. In the cognitive cohort, BioSync and concatenation obtained AUCs of 0.928 and 0.926, respectively. In the metabolic cohort, BioSync obtained accuracy/F1 of 0.764/0.766, compared with 0.756/0.758 for concatenation. The BSI correlated with latent severity in both cohorts ($r=0.91$ and $r=0.68$). A pure-attention ablation obtained cognitive-cohort AUC 0.911, locating the increase to 0.928 in the combined wide-and-deep architecture. With matched modality-dropout training, BioSync led concatenation at five of six cognitive-cohort corruption rates and at the highest metabolic-cohort rate. Its cognitive-cohort AUC was also higher than five published digital-biomarker reference values, although differences in datasets and tasks preclude a controlled benchmark claim. Comparison with single-modality, early-fusion, and late-fusion designs across six prespecified criteria identifies the model's computational properties; validation on real cohorts remains necessary.
Abstract:Cardiac, neural, behavioral, and speech measurements from wearable and mobile devices provide partial, noise-sensitive views of physiological state. BioSync combines these measurements into the \textbf{BioSync Index (BSI)}, a continuous composite digital biomarker defined under the BEST framework. The model applies multi-head self-attention to modality tokens and adds a linear branch whose hypothesis class includes standard feature concatenation. This architecture is motivated by latent-variable measurement theory and by the possibility that joint observations contain information unavailable from individual modalities. We evaluated BioSync on two literature-informed synthetic cohorts: a four-modality cognitive-decline cohort using HRV, EEG, actigraphy, and speech, and a metabolic-autonomic cohort structured around the public AI-READI wearable schema. In the cognitive cohort, BioSync and concatenation obtained AUCs of 0.928 and 0.926, respectively. In the metabolic cohort, BioSync obtained accuracy/F1 of 0.764/0.766, compared with 0.756/0.758 for concatenation. The BSI correlated with latent severity in both cohorts ($r=0.91$ and $r=0.68$). A pure-attention ablation obtained cognitive-cohort AUC 0.911, locating the increase to 0.928 in the combined wide-and-deep architecture. With matched modality-dropout training, BioSync led concatenation at five of six cognitive-cohort corruption rates and at the highest metabolic-cohort rate. Its cognitive-cohort AUC was also higher than five published digital-biomarker reference values, although differences in datasets and tasks preclude a controlled benchmark claim. Comparison with single-modality, early-fusion, and late-fusion designs across six prespecified criteria identifies the model's computational properties; validation on real cohorts remains necessary.
Artificial Intelligence (cs.AI); Information Retrieval (cs.IR)
arXiv:2609.04504 [cs.AI]
(or arXiv:2609.04504v1 [cs.AI] for this version)
https://doi.org/10.48550/arXiv.2609.04504 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Text integral sub licența deschisă a publicației · 326 cuvinte
Subiecte conexe
RAMamba-Net: A Reliability-Aware and Mamba-Based Multimodal Fusion Network for Auditory Attention Detection
arXiv · 12 sept. 2026
Multimodal Surface EMG Hand Gesture Recognition Using Query-Based Transformers for Prosthetic Control
arXiv · 28 iul. 2026
RAFM-SER++: A Lightweight Multimodal Emotion Recognition Framework for Real-Time Behavioral Monitoring in Surveillance Systems
arXiv · 9 sept. 2026
Modality Discrepancy Transformer for Ambivalence and Hesitancy Recognition
arXiv · 18 sept. 2026