This paper presents a plug-and-play framework using Concept Bottleneck Models to debug medical imaging AI by isolating causal features from spurious correlations in ultrasound and X-ray data. By enabling concept-level interventions, the method facilitates expert validation and counterfactual generation for targeted fine-tuning without sacrificing predictive performance. This approach directly addresses the interpretability bottleneck critical for deploying reliable clinical deep learning systems.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Beyond Explanation: Debugging Medical Imaging Models via Concept Intervention

arXiv2 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2610.09031v1 Announce Type: cross Abstract: Medical imaging models often operate as black boxes, limiting interpretability and systematic debugging. We introduce an easy-to-use, plug-and-play framework for concept-based interpretation and model refinement. By aligning a single-modality encoder to BioMedCLIP, we construct a Concept Bottleneck Model (CBM) that enables concept-level interventions. These interventions allow us to isolate causal versus spuriously correlated concepts, validate insights with domain experts, and generate counterfactual samples for targeted fine-tuning. We evaluate our framework on a Mayo Clinic ultrasound dataset and the CheXpert 5x200 chest X-ray dataset. Results demonstrate that concept intervention enables reliable model diagnosis while maintaining, and occasionally improving predictive performance via guided fine-tuning. Our findings highlight the practical value of this framework for controlled, interpretable refinement of clinical deep learning models.

Abstract:Medical imaging models often operate as black boxes, limiting interpretability and systematic debugging. We introduce an easy-to-use, plug-and-play framework for concept-based interpretation and model refinement. By aligning a single-modality encoder to BioMedCLIP, we construct a Concept Bottleneck Model (CBM) that enables concept-level interventions. These interventions allow us to isolate causal versus spuriously correlated concepts, validate insights with domain experts, and generate counterfactual samples for targeted fine-tuning. We evaluate our framework on a Mayo Clinic ultrasound dataset and the CheXpert 5x200 chest X-ray dataset. Results demonstrate that concept intervention enables reliable model diagnosis while maintaining, and occasionally improving predictive performance via guided fine-tuning. Our findings highlight the practical value of this framework for controlled, interpretable refinement of clinical deep learning models.

Computer Vision and Pattern Recognition (cs.CV); Machine Learning (cs.LG)

arXiv:2610.09031 [cs.CV]

(or arXiv:2610.09031v1 [cs.CV] for this version)

https://doi.org/10.48550/arXiv.2610.09031 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 220 cuvinte

Subiecte conexe