Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchMachine learning

analiza aiqbench

This study applies Sequential Neural Posterior Estimation to fMRI data, offering a Bayesian framework that disentangles scanner noise from true neural variability in functional connectivity. By modeling BOLD dynamics as coupled Ornstein-Uhlenbeck processes, the research provides concrete guidelines for optimizing scan duration and spatial resolution, demonstrating significant efficiency gains at higher magnetic field strengths. The work directly addresses experimental design challenges in neuroimaging through advanced probabilistic machine learning techniques.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Bayesian Uncertainty Quantification for fMRI Functional Connectivity via Simulation-Based Inference

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2609.30445v1 Announce Type: cross Abstract: Optimizing fMRI scan duration and spatial resolution is critical for experimental design, yet traditional correlation-based approaches cannot quantify uncertainty or disentangle scanner measurement noise from true neural variability across subjects. Without principled uncertainty bounds, researchers cannot know whether a protocol is long enough to reliably estimate connectivity, or whether between-subject differences reflect biological variation or noise. We present a Bayesian framework modeling BOLD dynamics as coupled Ornstein-Uhlenbeck processes, using Sequential Neural Posterior Estimation to obtain connectivity posteriors while accounting for frequency-independent measurement noise across the BOLD spectrum. Applied to N = 28 healthy controls (55 scans) at 7T using a functional network atlas (65 DMN regions), the framework quantifies uncertainty across its sources: scanner noise, subject variability, and acquisition length. Spatial analysis identifies a mean of 46 voxels per ROI, roughly half of typical region sizes, as sufficient to achieve 90% of asymptotic precision. At the single-subject level, 7T reaches its within-session precision plateau in approximately 7 minutes versus 10 minutes for 3T, a 40% reduction in required scan time, providing the first direct, model-based quantification of the scan-time advantage conferred by higher field strength. At the population level, 3T requires roughly 37 times more per-subject scan time than 7T for the pooled curves to converge, confirming a consistent advantage of higher field strength at every timescale. Together these findings provide concrete, scanner-specific guidance for protocol optimization, with direct implications for reducing acquisition costs and improving the reliability of connectivity-based clinical biomarkers. We provide code enabling researchers to derive these bounds from their own data.

Abstract:Optimizing fMRI scan duration and spatial resolution is critical for experimental design, yet traditional correlation-based approaches cannot quantify uncertainty or disentangle scanner measurement noise from true neural variability across subjects. Without principled uncertainty bounds, researchers cannot know whether a protocol is long enough to reliably estimate connectivity, or whether between-subject differences reflect biological variation or noise. We present a Bayesian framework modeling BOLD dynamics as coupled Ornstein-Uhlenbeck processes, using Sequential Neural Posterior Estimation to obtain connectivity posteriors while accounting for frequency-independent measurement noise across the BOLD spectrum. Applied to N = 28 healthy controls (55 scans) at 7T using a functional network atlas (65 DMN regions), the framework quantifies uncertainty across its sources: scanner noise, subject variability, and acquisition length. Spatial analysis identifies a mean of 46 voxels per ROI, roughly half of typical region sizes, as sufficient to achieve 90% of asymptotic precision. At the single-subject level, 7T reaches its within-session precision plateau in approximately 7 minutes versus 10 minutes for 3T, a 40% reduction in required scan time, providing the first direct, model-based quantification of the scan-time advantage conferred by higher field strength. At the population level, 3T requires roughly 37 times more per-subject scan time than 7T for the pooled curves to converge, confirming a consistent advantage of higher field strength at every timescale. Together these findings provide concrete, scanner-specific guidance for protocol optimization, with direct implications for reducing acquisition costs and improving the reliability of connectivity-based clinical biomarkers. We provide code enabling researchers to derive these bounds from their own data.

Machine Learning (stat.ML); Machine Learning (cs.LG)

arXiv:2609.30445 [stat.ML]

(or arXiv:2609.30445v1 [stat.ML] for this version)

https://doi.org/10.48550/arXiv.2609.30445 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 352 cuvinte

Subiecte conexe