Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchMachine learning

analiza aiqbench

This study investigates how normalization strategies impact the generalization of wrist EDA affect-recognition models, revealing that pretraining with expert artifact annotations significantly outperforms self-supervised approaches when held-out user data is excluded. The findings highlight a critical methodological gap in current literature, where many studies fail to report whether normalization statistics derive from training or test subjects, thereby inflating reported model benefits. For practitioners deploying wearable AI, this underscores the necessity of distinguishing between first-use performance and calibrated results to ensure robust, privacy-preserving deployment.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

Artifact Annotations Partially Substitute for Per-User Calibration: SAFE-EDA and a Normalization-Controlled Evaluation of Wrist-EDA Affect Recognition

arXiv3 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2610.01692v1 Announce Type: new Abstract: Wrist electrodermal activity (EDA) differs in amplitude from one person to the next, so affect-recognition models normalize their input before classification. Studies that test such models on held-out subjects seldom report where the normalization statistics come from, yet statistics computed from the held-out subject's own recording give the model information that a device does not have when it is first worn. We asked how this choice alters the measured benefit of pretraining. A compact convolutional network, SAFE-EDA, was pretrained on expert artifact annotations from 43 subjects and compared with the same network trained from scratch on the Wearable Stress and Affect Detection (WESAD) dataset (15 subjects, leave-one-subject-out), with two normalization sources crossed with four window hops. When the statistics came only from training subjects, pretraining raised macro-F1 by 0.078 to 0.227; when they came from the held-out user's full recording, the gain fell to between 0.020 and 0.050 and was no longer significant. Artifact supervision was far more useful than self-supervised pretraining on the same recordings (0.078 versus 0.008). Across 13 configurations in two datasets, the pretrained network was better in 12, but on the second dataset (26 subjects) per-user normalization increased the gain instead of reducing it, so the interaction depends on the data. Only five of 50 published WESAD studies state which data were used for normalization. Reporting this choice is necessary to separate first-use performance from performance after calibration.

Abstract:Wrist electrodermal activity (EDA) differs in amplitude from one person to the next, so affect-recognition models normalize their input before classification. Studies that test such models on held-out subjects seldom report where the normalization statistics come from, yet statistics computed from the held-out subject's own recording give the model information that a device does not have when it is first worn. We asked how this choice alters the measured benefit of pretraining. A compact convolutional network, SAFE-EDA, was pretrained on expert artifact annotations from 43 subjects and compared with the same network trained from scratch on the Wearable Stress and Affect Detection (WESAD) dataset (15 subjects, leave-one-subject-out), with two normalization sources crossed with four window hops. When the statistics came only from training subjects, pretraining raised macro-F1 by 0.078 to 0.227; when they came from the held-out user's full recording, the gain fell to between 0.020 and 0.050 and was no longer significant. Artifact supervision was far more useful than self-supervised pretraining on the same recordings (0.078 versus 0.008). Across 13 configurations in two datasets, the pretrained network was better in 12, but on the second dataset (26 subjects) per-user normalization increased the gain instead of reducing it, so the interaction depends on the data. Only five of 50 published WESAD studies state which data were used for normalization. Reporting this choice is necessary to separate first-use performance from performance after calibration.

12 pages, 6 figures, 6 tables, plus 2 pages of supplementary material. Code: this https URL

Machine Learning (cs.LG); Signal Processing (eess.SP)

arXiv:2610.01692 [cs.LG]

(or arXiv:2610.01692v1 [cs.LG] for this version)

https://doi.org/10.48550/arXiv.2610.01692 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 345 cuvinte

Subiecte conexe