A Master-Salve Robot Manipulator for Needle-Based Teleoperation in MRI Chamber

arXiv2 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2608.06354v1 Announce Type: new Abstract: We present a MR safe, master-slave robot manipulator for abdominal interventions in the MRI chamber. A human operated 2+1-DoF master controller manipulator transmits motion and force to a 2+1-DoF slave manipulator via fluid transmission. Jointly, a digital master controller provides multimodal control capability beyond common split axis or mode switchable hybrid human-digital controller configurations found in previous studies. High input impedance, low-leakage, elastomeric fluid actuators are delegated to remote angulation control. Low-friction graphite piston cylinders are delegated to needle insertion axis remote actuation given the sub-newton force transparency and sub-millimeter motion transmission over bedside fluid piping lengths. The device enables real-time MRI guided interventions allowing manual, digital, hybrid, and collaborative control modes. Collaborative tasks such as assisted tissue penetration, fault-driven virtual fixture, and motion compensation through feedback control are presented in this paper. Preliminary MR scanner results demonstrate manipulator functional viability for an in-vivo pig experiment in bedside, manual control mode configuration.

Abstract:We present a MR safe, master-slave robot manipulator for abdominal interventions in the MRI chamber. A human operated 2+1-DoF master controller manipulator transmits motion and force to a 2+1-DoF slave manipulator via fluid transmission. Jointly, a digital master controller provides multimodal control capability beyond common split axis or mode switchable hybrid human-digital controller configurations found in previous studies. High input impedance, low-leakage, elastomeric fluid actuators are delegated to remote angulation control. Low-friction graphite piston cylinders are delegated to needle insertion axis remote actuation given the sub-newton force transparency and sub-millimeter motion transmission over bedside fluid piping lengths. The device enables real-time MRI guided interventions allowing manual, digital, hybrid, and collaborative control modes. Collaborative tasks such as assisted tissue penetration, fault-driven virtual fixture, and motion compensation through feedback control are presented in this paper. Preliminary MR scanner results demonstrate manipulator functional viability for an in-vivo pig experiment in bedside, manual control mode configuration.

Robotics (cs.RO)

arXiv:2608.06354 [cs.RO]

(or arXiv:2608.06354v1 [cs.RO] for this version)

https://doi.org/10.48550/arXiv.2608.06354 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 245 cuvinte

Subiecte conexe