analiza aiqbench
This study demonstrates that adapting the MedSAM3 foundation model with LoRA requires only a handful of annotated cases to achieve clinically competitive segmentation performance across multiple abdominal organs and cardiac structures. By drastically reducing annotation needs and training time compared to specialist systems, this approach effectively addresses data scarcity bottlenecks in medical imaging workflows without sacrificing accuracy.
A Few Cases Are All You Need: An Empirical Study of Annotation-Efficient LoRA Fine-Tuning of MedSAM3
arXiv:2608.18731v1 Announce Type: cross Abstract: Medical image segmentation is essential for clinical workflows such as treatment planning and disease assessment. While specialist tools like TotalSegmentator and MRSegmentator achieve strong performance, they require large annotated datasets for training. Medical foundation models offer a promising alternative through large-scale pretraining that reduces the annotation burden for new tasks, but zero-shot performance remains limited. Parameter-efficient adaptation via Low-Rank Adaptation (LoRA) enables efficient specialization with few trainable parameters, but a key question remains: how many expert-annotated cases are needed to achieve clinically useful segmentation performance? We address this by adapting MedSAM3 with LoRA for five abdominal organs (liver, kidneys, spleen, gallbladder, and pancreas) in CT and MRI using only 1, 2, 5, and 10 annotated cases, evaluating on AMOS22 dataset. With just 10 cases, models achieve performance competitive with specialist systems trained on orders of magnitude more data. Notably, this includes reliable gallbladder segmentation (Dice 0.68 CT, 0.59 MRI) where existing tools fail almost completely (Dice 0.0004), while remaining within 5--10% of MRSegmentator for liver, kidneys, and spleen using over 100 times fewer annotations. Furthermore, external validation on the Whole Heart Segmentation dataset shows that the approach extends to cardiac segmentation, a use case beyond the scope of TotalSegmentator (MRI) and MRSegmentator, achieving competitive left ventricle (LV) performance with only 10 annotated cases. Training requires only3--5,hours per organ on a single GPU, approximately 2--3 times faster than nnU-Net. These findings suggest that ten annotated cases are sufficient for clinically useful segmentation, effectively reducing bottlenecks for both image annotation and training time.
Abstract:Medical image segmentation is essential for clinical workflows such as treatment planning and disease assessment. While specialist tools like TotalSegmentator and MRSegmentator achieve strong performance, they require large annotated datasets for training. Medical foundation models offer a promising alternative through large-scale pretraining that reduces the annotation burden for new tasks, but zero-shot performance remains limited. Parameter-efficient adaptation via Low-Rank Adaptation (LoRA) enables efficient specialization with few trainable parameters, but a key question remains: how many expert-annotated cases are needed to achieve clinically useful segmentation performance? We address this by adapting MedSAM3 with LoRA for five abdominal organs (liver, kidneys, spleen, gallbladder, and pancreas) in CT and MRI using only 1, 2, 5, and 10 annotated cases, evaluating on AMOS22 dataset. With just 10 cases, models achieve performance competitive with specialist systems trained on orders of magnitude more data. Notably, this includes reliable gallbladder segmentation (Dice 0.68 CT, 0.59 MRI) where existing tools fail almost completely (Dice 0.0004), while remaining within 5--10% of MRSegmentator for liver, kidneys, and spleen using over 100 times fewer annotations. Furthermore, external validation on the Whole Heart Segmentation dataset shows that the approach extends to cardiac segmentation, a use case beyond the scope of TotalSegmentator (MRI) and MRSegmentator, achieving competitive left ventricle (LV) performance with only 10 annotated cases. Training requires only3--5,hours per organ on a single GPU, approximately 2--3 times faster than nnU-Net. These findings suggest that ten annotated cases are sufficient for clinically useful segmentation, effectively reducing bottlenecks for both image annotation and training time.
Computer Vision and Pattern Recognition (cs.CV); Artificial Intelligence (cs.AI)
arXiv:2608.18731 [cs.CV]
(or arXiv:2608.18731v1 [cs.CV] for this version)
https://doi.org/10.48550/arXiv.2608.18731 Focus to learn more arXiv-issued DOI via DataCite (pending registration)
arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.
Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.
Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.
Text integral sub licența deschisă a publicației · 351 cuvinte
Subiecte conexe

Research Note: Filtering Subversion-Relevant Information From Pretraining Data Is Feasible
LessWrong · 5 oct. 2026

PIRAMID: Progress and Plans
LessWrong · 27 iul. 2026
Links #5: 2026/07
LessWrong · 31 iul. 2026

Exploring self-distilled reasoning for supervised fine-tuning with Amazon Nova
AWS · 21 iul. 2026