Sari la conținut

Română · beta. Traducerea a fost făcută automat și este încă în curs de revizuire. Citește pagina în engleză

perspectiva aiqbenchCalcul cuantic

analiza aiqbench

This study establishes that $1/f$ noise in mechanical resonators is fundamentally governed by device volume rather than quality factor, revealing a universal scaling law that invalidates previous assumptions about thermomechanical limits. By demonstrating that mass resolution scales with the square root of this volume-dependent noise floor, the research provides critical constraints for designing ultra-sensitive quantum sensors and nanoscale frequency-shift devices. These findings are essential for researchers aiming to push mechanical systems toward their fundamental quantum limits without relying on spurious quality factor improvements.
Sursă care acoperăarXiv
Ce este aceastaLectura unui model asupra articolului și a acoperirii conexe, scrisă pentru aiqbench. Nu sunt cuvintele publicației.

1/f frequency noise in mechanical resonators scales inversely with volume, not with quality factor

arXiv1 min de cititArticolul și perspectiva sunt în engleză.

arXiv:2609.16668v1 Announce Type: cross Abstract: Mechanical frequency-shift sensors have never reached their fundamental thermomechanical or quantum limits. Every material, size, and transduction scheme yet examined yields a $1/f$ floor 1-3 orders higher, with a flicker-noise coefficient $h_{-1} \propto 1/V_{\varepsilon}$. Surveying the published record, I find the invariant $h_{-1}\,V_{\varepsilon} \equiv \sigma_A ^2\, V_{\varepsilon}/(2\ln 2)$ independent of device size across 13 decades; volume-independent noise is excluded by 9$\sigma$, site-averaging by 3.8$\sigma$. No $Q$ dependence appears: reported $Q^{-n}$ laws scale equivalently when $Q$ and volume co-vary; only volume scaling survives when they do not. Mass resolution follows as $|\delta m| \propto \sqrt{h_{-1}\,V_{\varepsilon} \cdot V}$.

Abstract:Mechanical frequency-shift sensors have never reached their fundamental thermomechanical or quantum limits. Every material, size, and transduction scheme yet examined yields a $1/f$ floor 1-3 orders higher, with a flicker-noise coefficient $h_{-1} \propto 1/V_{\varepsilon}$. Surveying the published record, I find the invariant $h_{-1}\,V_{\varepsilon} \equiv \sigma_A ^2\, V_{\varepsilon}/(2\ln 2)$ independent of device size across 13 decades; volume-independent noise is excluded by 9$\sigma$, site-averaging by 3.8$\sigma$. No $Q$ dependence appears: reported $Q^{-n}$ laws scale equivalently when $Q$ and volume co-vary; only volume scaling survives when they do not. Mass resolution follows as $|\delta m| \propto \sqrt{h_{-1}\,V_{\varepsilon} \cdot V}$.

Mesoscale and Nanoscale Physics (cond-mat.mes-hall); Quantum Physics (quant-ph)

arXiv:2609.16668 [cond-mat.mes-hall]

(or arXiv:2609.16668v1 [cond-mat.mes-hall] for this version)

https://doi.org/10.48550/arXiv.2609.16668 Focus to learn more arXiv-issued DOI via DataCite (pending registration)

SM_v112_2026-09-14.pdf

arXivLabs is a framework that allows collaborators to develop and share new arXiv features directly on our website.

Both individuals and organizations that work with arXivLabs have embraced and accepted our values of openness, community, excellence, and user data privacy. arXiv is committed to these values and only works with partners that adhere to them.

Have an idea for a project that will add value for arXiv's community? Learn more about arXivLabs.

Text integral sub licența deschisă a publicației · 196 cuvinte

Subiecte conexe